KDC‑EX‑FPMNVTI2Ea4b10xc1d25 is ATEX, IECEx, CNEX & DNV type‑approved fixed dual‑spectrum explosion‑proof camera, optimised for onshore petrochemical plants, tank farms, chemical terminals, mines and port hazardous‑zone safety monitoring. Visible‑light channel:4MP 10× motorised optical zoom (4.8‑48 mm); Thermal channel:384×288 uncooled vanadium‑oxide detector with 25 mm athermal lens, supporting ‑20 ℃ ~ 650 ℃ dual‑range temperature measurement and real‑time fire‑point early‑warning. 316L stainless‑steel IP68 housing, built‑in window wiper, optional heater‑fan assembly. Multi‑power‑input: PoE+, AC12‑36V, DC12‑57V, AC100‑240V. Operating temperature ‑40 ℃ ~ +70 ℃. Certified for Zone 1/2 gas, Zone 21/22 dust hazardous locations for on‑shore energy and heavy‑industry facilities.
On‑shore petrochemical, oil‑depot, mine and heavy‑industrial hazardous‑zone projects face these core challenges:
KDC‑EX‑FPMNVTI2Ea4b10xc1d25 addresses all above‑mentioned pain‑points: Multi‑certified land‑focused 4MP 10× dual‑spectrum explosion‑‑proof fixed camera with built‑in wiper, 316L stainless‑steel IP68 housing, wide‑temperature adaptability, professional thermal temperature‑measurement & fire‑detection capability, multi‑power‑supply options. Specially developed for visual monitoring plus thermal risk early‑warning for on‑shore petrochemical plants, oil depots, mines and port hazardous‑zone sites.
✅ Petrochemical & Chemical Industry: Refineries, crude‑oil tank farms, chemical storage terminals, process production units | Hazardous‑zone fixed‑point dual‑spectrum monitoring for tank‑groups, pipe‑galleries, pump‑houses and loading‑unloading areas; equipment over‑heat inspection & fire‑risk early‑warning, Zone 1/2 gas, Zone 21/22 dust locations ✅ Oil & Energy Storage Sites: On‑shore oil depots, land‑based LNG storage stations | Tank‑farm perimeter visual monitoring, non‑contact temperature inspection of storage‑tank and valve‑equipment, real‑time fire‑point early‑warning ✅ Mining & Heavy‑Duty Industry: Coal‑chemical plants, mine explosive‑classified production workshops | Explosive‑hazard area fixed‑point visual + thermal safety monitoring, over‑temperature risk pre‑alert ✅ Port & Terminal Hazardous Zones: Chemical‑handling port terminals, dangerous‑goods storage yards | Coastal land‑based hazardous‑zone dual‑spectrum monitoring under dust‑corrosion and salt‑fog environment
Installation: Wall‑mount or column‑platform mounting with multi‑angle adjustment. Must adopt matching ATEX‑certified explosion‑proof cable glands and junction boxes. Compatible with KAIDUNTECH complete explosion‑proof surveillance accessories to build end‑to‑end hazardous‑zone monitoring solution for on‑shore industrial projects.
✅ Full‑Set Authoritative Explosion‑Proof Certifications for Land Hazardous Zones Obtains ATEX, IECEx, CNEX and DNV Type Approval. Explosion‑proof rating: Ex db I Mb; Ex db IIC T6 Gb (Zone 1&2); Ex tb IIIC T80 ℃ Db (Zone 21&22). Complete set of certification documents available for EPC project review, hazardous‑area safety‑inspection and acceptance submission for petrochemical and heavy‑industry projects.
✅ 4MP Visible‑Light 10× Motorised Zoom with Industry‑Validated DORI Performance Visible‑light channel:1/2.8‑inch 4MP progressive‑scan CMOS sensor; 10× motorised optical zoom 4.8‑48 mm; FOV H:56.15°‑6.12°, V:33.4°‑3.44°. Excellent DORI detection‑observe‑recognize‑identify indexes for personnel, vehicles and boats, meeting long‑distance visual inspection requirements for tank‑farms and pipe‑galleries. Supports adaptive defog, EIS electronic image stabilisation, 3D‑DNR noise‑reduction, ICR auto day‑night switch.
✅ Professional 384×288 Uncooled Thermal Imaging & Reliable Fire‑Risk Early‑Warning Thermal channel:384×288 vanadium‑oxide uncooled focal‑plane detector, 25 mm athermal fixed lens, NETD ≤40 mK. Dual‑range temperature‑measurement:‑20 ℃~150 ℃ low‑temp mode /100 ℃~650 ℃ high‑temp mode with auto gain‑switch, accuracy ±2 ℃ or ±2% whichever greater. Supports multi‑point / line / polygon‑region temperature‑measurement rule, isotherm setting, real‑time fire‑point detection, temperature‑abnormality linkage‑alarm, thermal snapshot and historical‑temperature‑data export for post‑event safety‑analysis. Multiple thermal colour‑palettes, NUC non‑uniformity correction and digital detail‑enhancement.
✅ Built‑in Explosion‑Proof Window Wiper for Complex Industrial Pollution Scenarios Integrated explosion‑proof wiper removes industrial dust, chemical residues and rain‑water stains on lens surface. Cleaning operation completes without opening explosion‑proof housing, eliminating explosion‑safety risks caused by manual disassembly inside hazardous‑zone sites, ensuring stable and clear imaging in dusty and polluted on‑shore industrial environments.
✅ Robust 316L Stainless‑Steel IP68 Housing & Optional Heater‑Fan Module 316L stainless‑steel enclosure with optional powder‑coated surface finish. IP68 dust‑proof and water‑tight protection. Optional heater‑fan assembly for low‑temperature and high‑humidity outdoor industrial sites. Operating temperature:‑40 ℃ ~ +70 ℃, humidity<100 %RH(non‑condensing), resisting industrial corrosive vapour, dust and heavy‑rain outdoor working conditions.
✅ Multiple‑Flexible‑Power‑Supply Options & Rich‑Protocol Compatibility Multi‑mode power‑input: PoE+, AC12‑36V, DC12‑57V, AC100‑240V; max power consumption ≤60 W. Supports H.265 / H.264 dual‑stream encoding for visible and thermal channels; Micro‑SD card local storage up to 256 GB for broken‑network supplementary recording. Complies with ONVIF, GB/T28181, Modbus‑TCP, MQTT and SDK secondary‑development interface, convenient for docking with third‑party industrial VMS and thermal‑monitoring platforms.
| Item | Parameter |
|---|---|
| Model | KDC‑EX‑FPMNVTI2Ea4b10xc1d25 4MP 10X Explosion‑Proof Fixed Dual‑Spectrum Camera (Land‑Based Hazardous‑Zone) |
| Visible‑Light Channel | |
| Sensor | 1/2.8‑inch 4MP Progressive‑Scan CMOS |
| Optical Zoom | 10× motorised zoom; focal length 4.8‑48 mm |
| Visible FOV | H:56.15°~6.12°;V:33.4°~3.44° |
| Min. Illumination | Color:0.001Lux; B/W:0.0005Lux |
| Image Enhancement | Adaptive defog, EIS anti‑shake, 3D‑DNR, ICR day‑night switch |
| Visible DORI | Person:Detect48~479.98m; Observe19.05~190.47m; Recognize9.6~96m; Identify4.8~48mCar:Detect144~1439.94m; Observe57.14~571.41m; Recognize28.8~288m; Identify14.4~144mBoat:Detect480~4800m; Observe190.48~1904.7m; Recognize96~960m; Identify48~480m |
| Thermal Imaging Channel | |
| Detector | Vanadium‑oxide uncooled FPA,384×288,12 μm |
| Frame Rate | 50 Hz |
| Spectral Band | 7.5‑14 μm; NETD ≤40 mK |
| Thermal Lens | 25 mm athermal fixed‑focus lens; FOV H:10.5°×V:7.9° |
| Electronic Zoom | 1.0‑8.0× continuous zoom |
| Temperature‑Measurement | Low:‑20 ℃~150 ℃; High:100 ℃~650 ℃; auto gain‑switch; Accuracy ±2 ℃ or ±2% whichever greater |
| Thermal Functions | Multi‑point / line / polygon‑region measurement, isotherm setting, fire‑point detection, temp‑abnormality linkage‑alarm, thermal snapshot, historical‑data export, multiple palettes, NUC correction |
| Mechanical & Hardware | |
| Special Mechanical | Built‑in explosion‑proof window wiper; Optional heater & fan module |
| Video Encoding | H.265 / H.264 dual‑stream for visible & thermal channel |
| Local Storage | Micro‑SD up to 256 GB, broken‑network supplementary recording |
| Protocol | ONVIF, GB/T28181, Modbus‑TCP, MQTT, SDK, full TCP/IP suite |
| Power Supply | PoE+, AC12‑36V, DC12‑57V, AC100‑240V optional; ≤60W |
| Explosion‑Proof Grade | Ex db I Mb; Ex db IIC T6 Gb(Zone1&2); Ex tb IIIC T80℃ Db(Zone21&22) |
| Certifications | ATEX, IECEx, CNEX, DNV Type Approval |
| Housing | 316L stainless‑steel / 304 stainless‑steel; powder‑coated optional |
| Ingress Protection | IP68 |
| Operating Environment | ‑40 ℃ ~ +70 ℃, humidity <100 %RH non‑condensing |
| Cable Entry | Dual M25×1.5 entry holes |
| Dimension(L×W×H) | 285 × 367 × 330 mm |
| Net Weight | ≤20 kg |
| Installation | Wall‑mount / Column‑platform multi‑angle adjustable mounting |
| Item | Details |
|---|---|
| Standard Model | 3‑4‑week production lead‑time upon deposit receipt |
| Custom‑modified Version | 5‑6‑week lead‑time for surface‑finish, heater‑fan configuration, interface or software‑feature adjustments |
Deliverables: Datasheet, mechanical dimension drawings, copies of ATEX/IECEx/CNEX/DNV certificates, operation manual for petrochemical / heavy‑industry EPC project review and safety‑acceptance submission.
Warranty Terms ‑ 12‑month standard full‑unit warranty. Extended warranty duration negotiable via separate commercial quotation. ‑ Defective hardware supports factory‑return repair or replacement service. ‑ Value‑added support: remote configuration‑guidance, complete technical‑document support for on‑shore hazardous‑zone surveillance new‑build and reconstruction projects.
Packaging & Logistics: Export‑grade wooden‑crate packaging. Supports EXW, FOB and other international‑trade terms. Consolidated shipment available with explosion‑proof accessories and recording equipment.
⚠️ Reminder: KDC‑EX‑FPMNVTI2Ea4b10xc1d25 is multi‑certified dual‑spectrum explosion‑proof fixed camera with wiper, applicable for on‑shore petrochemical, oil‑depot, mine and port hazardous‑zone deployment. Off‑the‑shelf stock cannot be guaranteed. Please place orders sufficiently ahead of project milestones. Installation must strictly adopt ATEX‑qualified explosion‑proof cable‑glands & junction boxes and comply with local hazardous‑area safety‑regulations.
‑Project Challenges: Large‑scale petrochemical tank‑farm new‑build project. Need certified dual‑spectrum explosion‑‑proof fixed cameras for Zone 1/2 and Zone 21/22 hazardous zones. Require 10× optical‑zoom for long‑distance visual inspection of tanks and valves; thermal‑imaging for non‑contact temperature‑measurement and real‑time fire‑point early‑warning; built‑in wiper for dust‑rain pollution; optional heater‑fan for outdoor large‑temperature fluctuation; multi‑power‑supply options; 316L IP68 housing resisting chemical‑vapour corrosion. Need docking with plant existing VMS & thermal‑monitoring platform. Equipment must pass hazardous‑zone safety‑inspection and EPC acceptance. ‑Solution: Deploy KDC‑EX‑FPMNVTI2Ea4b10xc1d25 dual‑spectrum explosion‑proof fixed cameras, adopt column‑platform installation at tank‑farm support‑pillars, equip certified explosion‑proof cable‑glands and junction boxes, configure wiper strategy, temperature‑measurement rules and fire‑alarm trigger parameters. Complete docking with plant existing monitoring platform. ‑Outcome: Full‑set explosion‑proof certification meets petrochemical hazardous‑zone acceptance requirements. Visible‑light channel realises long‑range visual inspection for tank‑farm key‑points. Thermal‑imaging monitors equipment temperature and triggers proactive fire‑risk early‑warning. Built‑in wiper keeps lens clean in dusty outdoor environment. Project passed hazardous‑zone safety‑acceptance.
‑Project Challenges: In‑service coastal oil‑depot reconstruction project. Need dual‑spectrum explosion‑proof fixed cameras for oil‑storage tank‑group hazardous zones. Require visual monitoring plus thermal over‑temperature & fire‑point detection; wiper for rain‑dust cleaning; compatible with existing monitoring platform for periodic safety‑inspection. ‑Solution: Install KDC‑EX‑FPMNVTI2Ea4b10xc1d25 dual‑spectrum explosion‑proof cameras with wall‑mount layout, finish network adaptation and thermal‑alarm parameter configuration. ‑Outcome: Stable dual‑spectrum monitoring for oil‑depot hazardous‑zone. Realises visual scene review together with non‑contact temperature‑inspection and fire‑risk pre‑warning. Built‑in wiper adapts to coastal rain‑dust working‑conditions. System completed safety‑acceptance for reconstruction‑project.
Q1: What explosion‑proof certifications and hazardous zones is this camera applicable to for land‑based projects? A: It holds ATEX, IECEx, CNEX and DNV Type Approval. Explosion‑proof grade Ex db I Mb; Ex db IIC T6 Gb for Zone 1 & 2 gas hazardous‑zone; Ex tb IIIC T80 ℃ Db for Zone 21 & 22 dust hazardous‑zone. Certification documents can be provided for petrochemical, oil‑depot EPC review and safety‑inspection submission.
Q2: What are the core advantages of dual‑spectrum (visible + thermal‑imaging) for tank‑farm scenarios? A: The 4MP 10× zoom visible‑light channel provides detailed visual scene, personnel & equipment observation. The 384×288 thermal channel performs non‑contact temperature‑measurement, detecting hidden hot‑spots and early‑smouldering fire‑sources even under smoke, fog or total‑darkness, implementing proactive safety early‑warning for tank‑farm and process‑unit hazardous‑zones.
Q3: Why built‑in wiper for on‑shore industrial sites? A: On‑shore petrochemical and oil‑depot sites accumulate industrial dust, chemical residues and rain‑water stains on lens window. Built‑in explosion‑proof wiper cleans lens without opening explosion‑proof housing, avoids explosion‑safety risk caused by manual disassembly in hazardous‑zone, guarantees continuous clear imaging in polluted outdoor industrial environment.
Q4: What thermal‑measurement and fire‑detection capabilities does this camera support? A: Dual‑range temperature‑measurement:‑20 ℃~150 ℃ low‑temperature mode / 100 ℃~650 ℃ high‑temperature mode with auto gain‑switch. Supports multi‑point / line / polygon‑region temperature‑measurement rule, isotherm setting, real‑time fire‑point detection, temperature‑abnormality linkage‑alarm, thermal snapshot and historical‑temperature‑data export for safety‑analysis.
Q5: What optional configurations are available for land‑based outdoor deployment? A: Optional heater‑fan module for low‑temperature / high‑humidity outdoor sites; powder‑coated housing surface finish. Please specify requirements during inquiry.
Q6: What power‑supply modes are suitable for on‑shore plant new‑build & reconstruction? A: Multi‑input power‑supply: PoE+, AC12‑36V, DC12‑57V, AC100‑240V, max power consumption ≤60 W, adapting to diversified power‑supply conditions of new‑build and reconstruction industrial‑sites.
Q7: What installation suggestions for land‑based hazardous‑zone? A: Supports wall‑mount and column‑platform multi‑angle adjustable mounting, suitable for plant outer‑walls, tank‑farm support‑pillars and equipment‑support‑frames. Must use matching ATEX‑certified explosion‑proof cable‑glands and junction boxes, strictly comply with local hazardous‑area installation‑specifications.
Q8: What accessories are recommended? Is customisation supported? A: Recommended accessories: KDR‑1500 Rubber Flexible Hose, KDSR‑1500 Stainless‑Steel Flexible Hose, EX‑KDP001 Explosion‑proof connector, KDJ004 / KDJ008 Explosion‑proof junction box, KDB006T anti‑shake stainless‑steel bracket. Custom‑order for surface‑finish, heater‑fan, interfaces and software‑features is supported, 5‑6‑week lead‑time upon requirement confirmation.
Q9: What are environmental‑working parameters for on‑shore outdoor deployment? A: Operating temperature:‑40 ℃ ~ +70 ℃; humidity below 100 %RH(non‑condensing); IP68 ingress‑protection; 316L stainless‑steel housing resists industrial corrosive‑vapour, dust and heavy‑rain outdoor working‑conditions.
‑ KDR‑1500 Rubber Flexible Hose
‑ KDSR‑1500 Stainless Steel Flexible Hose
‑ EX‑KDP001 Exd Type Explosion‑proof connector
‑ KDJ004 Exe Type Explosion‑proof Junction Box
‑ KDJ008 Exe Type Explosion‑proof Junction Box
‑ KDB006T Anti‑Shake Stainless‑Steel Bracket