DNV‑issued IECEx & ATEX certified three‑in‑one integrated explosion‑proof PTZ camera. Combines 4MP 33× optical‑zoom visible‑light, athermalized thermal imaging and built‑in gas‑detection module within single 316L‑grade explosion‑proof housing. For land‑based gas Zone 1 & Zone 2 hazardous‑area sites, delivering multi‑risk early‑warning including perimeter intrusion, equipment hot‑spot fire hazard and flammable‑gas leakage for refineries, chemical plants and oil depots.
Land‑based petrochemical, refinery and chemical industry projects face multi‑dimensional safety‑monitoring pain points:
This KDC‑EX‑PTNVTI2Ea4b33xc2d25 integrated PTZ solves above‑mentioned pain points. Visible‑light, thermal imaging and gas‑detection are built inside one certified explosion‑proof housing. When gas leakage, hot‑spot or perimeter intrusion occurs, it triggers linkage alarm with synchronous video snapshot and streaming for alarm visual verification, simplifying system architecture for land‑based hazardous‑area safety monitoring.
✅ On‑land Oil Refineries & Oil Depots: Tank farm, pump station and pipeline corridor monitoring. Detect flammable‑gas leakage, equipment hot‑spot risk and perimeter illegal intrusion for Zone 1 & Zone 2 gas hazardous locations. ✅ Chemical & Petrochemical Plants: Production workshop, reactor area and chemical raw‑material storage yards. Real‑time joint monitoring for gas leak, equipment over‑temperature and restricted‑zone access violations. ✅ Land‑based Compressor & Booster Stations: Monitor compressor sets and pressure‑regulating facilities; early warning for gas leakage, thermal anomaly and unauthorized personnel access. ✅ Hazardous‑chemical Storage Terminals: 24‑hour all‑weather safety surveillance for dangerous‑goods stacking and loading‑unloading zones; cross‑verify gas‑leak alarm with real‑time video & thermal images. ✅ Coal‑chemical Industrial Hazardous Zones: Multi‑risk safety monitoring for process areas, combining perimeter security, fire pre‑warning and combustible‑gas leakage detection.
Supports wall‑mount and column‑platform installation. Optional accessories: anti‑shake bracket, Exd‑type explosion‑proof junction box, rubber / stainless‑steel flexible hose for one‑stop project procurement.
表格
| Item | Parameter |
|---|---|
| Visible Image Sensor | 1/2.8” 4MP Progressive‑Scan CMOS |
| Visible Zoom | 33× optical zoom +16× digital zoom; zoom speed ~3.5s (wide‑tele) |
| Visible FOV | 60.5‑2.3° |
| Thermal Module | Athermalized fixed‑focus thermal lens |
| Built‑in Function | Integrated gas‑detection module (custom gas sensor type & measuring range on request) |
| PTZ Rotation | Pan: 0‑360° continuous rotation; Tilt: ‑90° ~ +90° |
| Video Encoding | H.265 / H.264 / MJPEG; multi‑stream output |
| Smart Alarms | Cross‑border, area intrusion, loitering, crowd gathering, fast‑motion, fire alarm, gas‑leakage linkage alarm, device fault alarm |
| External Interface | 36‑pin FFC: Network port, RS485, RS232, SDHC, Alarm In/Out, Audio In/Out, Power |
| Local Storage | Micro‑SD / SDHC card support |
| Supported Protocol | ONVIF Profile S / G, rich standard industrial network protocols |
| Explosion‑proof Grade | Ex db IMb (Zone1 & Zone2 gas hazardous area) |
| Housing Material | 316L Stainless‑steel / 304 stainless‑steel |
| Dimension | 462*290*478.5 mm |
| Installation Mode | Wall‑mount / column‑platform mounting |

Deliverables: Product datasheet, mechanical dimension drawings, copy of DNV‑issued IECEx / ATEX certificates and operation manuals for project submission and review.
Warranty Terms: 12‑month standard warranty for the complete unit. Extended warranty service is available upon separate commercial quotation. Faulty devices support factory‑return repair or replacement; remote technical commissioning guidance is provided. Complete technical‑document support for overseas land‑based projects.
Note: The gas‑detection sensor part follows dedicated sensor manufacturer’s warranty specification, gas sensor belongs to consumable component.
Packaging & Logistics: Export‑grade wooden‑crate packaging. Supports EXW, FOB and other trade terms; optional accessories can be consolidated for one‑batch shipment.
Reminder: Integrated gas‑detection dual‑light explosion‑proof PTZ is special industrial safety equipment. Stock is not guaranteed. Please arrange order placement ahead of project schedule.
Case 1 | Land‑based Refinery Tank‑Farm Multi‑risk Monitoring Project ‑Project Challenges: Zone 2 hazardous tank‑farm and pump‑skid area. The project required simultaneous monitoring for combustible‑gas leakage, equipment hot‑spot risks and perimeter intrusion. Existing separate gas‑detectors suffered high false‑alarm rate without video verification; multi‑device deployment caused complex cabling. Valid explosion‑proof certificates are mandatory for safety‑authority acceptance. ‑Solution: Deploy multiple KDC‑EX‑PTNVTI2Ea4b33xc2d25 integrated PTZ cameras on plant columns, equipped with anti‑shake brackets and explosion‑proof junction boxes. Configure linkage rules: gas‑leak / thermal‑hot‑spot / intrusion events trigger alarm together with visible‑thermal snapshot and video stream. ‑Outcome: Realises unified three‑risk monitoring within single device. Greatly reduces false‑alarm interference by visual alarm verification. Minimises manual entry frequency for staff inside high‑risk tank‑farm zones, successfully passed local safety regulatory acceptance.
Case 2 | Chemical‑Plant Hazardous‑Process‑Workshop Surveillance Project ‑Project Challenges: Zone 1 gas‑classified chemical production workshop with corrosive vapour. Needs to monitor reactor equipment over‑temperature, combustible‑gas leakage and unauthorized access to restricted zones. ‑Solution: Adopt KDC‑EX‑PTNVTI2Ea4b33xc2d25 explosion‑proof integrated PTZ, configure multi‑condition linkage alarms for on‑site risk events. ‑Outcome: Stable long‑term operation under corrosive industrial atmosphere. Real‑time early warning for multiple hazard sources, simplifies system architecture and satisfies project safety‑design requirements.
A: Certified for gas Zone 1 & Zone 2 with Ex db IMb rating. DNV‑issued IECEx & ATEX certification documents can be supplied for designer evaluation and safety‑authority acceptance. Not suitable for dust hazardous zones by default, please consult sales for dust‑proof variant options.
A: Default for typical flammable‑gases in petrochemical sites. Custom gas‑sensor types and measuring ranges are supported as custom‑order options. Please clarify gas‑detection requirements during inquiry.
A: Once gas concentration exceeds threshold, the unit triggers local & network alarm, meanwhile pushes visible‑light and thermal‑channel snapshot & video stream, so operators can verify alarm authenticity via real‑time video without rushing to site.
A: Supports H.265/H.264/MJPEG compression and mainstream standard network protocols. Video stream, thermal stream and alarm events can be transmitted to most mainstream industrial surveillance platforms.
A: Supports wall‑mount and column‑platform installation. Anti‑shake brackets, explosion‑proof junction boxes, flexible hoses are available as original optional accessories.
A: The whole camera unit enjoys 12‑month standard warranty. The gas sensor component follows sensor supplier’s separate warranty terms, as gas sensors are consumable parts with limited service life. Please consult sales for details.
A: Custom service is available for gas‑sensor specification, interfaces and functions. Please contact sales team for specification review, MOQ and lead‑time assessment.